TM 5-4610-218-12
semble the sludge concentrator valves and piping.
(6) Repair or replace all defective parts.
the sludge concentrator valves and piping.
Section XIV. MAINTENANCE OF ERDLATOR WASTE
WARNING
d. Reassembly. Refer to figure 4-60 and
reas-
semble the piping.
Dry cleaning solvent, P-D-680, used to
clen parts, is potentially dangerous.
the waste water piping between the erdlator tank
Avoid repeated and prolonged
and outlet in van.
breathing of the vapors and skin con-
tact with the liquid. Do not use near
4-58. Waste Water Piping Between Wet Well
open flame or excessive heat. Use in a
and Erdlator Tank Outlet Piping.
well-ventilated area The flash-point
of P-D-680 is 100-138 F (38-59 C).
remove waste water piping between the wet well
and erdlator tank outlet piping.
4-57. Waste Water Piping Between Bottom of
b. Disassembly. Refer to figure 4-63 and
disas-
Erdlator Tank and Outlet in Van.
semble piping.
c. Clean, Inspect and Repair.
waste water piping between bottom of the erdlator
(1) Clean all parts with dry cleaning solvent
tank and outlet in van.
P-D-680.
b. Disassembly. Refer to figure 4-60 and
dis-
(2) Inspect all parts for damage.
assemble the piping.
(3) Repair or replace all damaged or defective
c. Clean, Inspect and Repair.
parts.
(1) Clean all parts with dry clening solvent P-
D-680.
d. Reassembly. Refer to figure 4-63 and
reas-
semble piping.
(2) Inspect all parts for damage.
(3) Repair or replace all damaged parts.
and install waste water piping between wet well
and erdlator tank outlet piping.
4-105