TM5-4610-233-13&P
REMOVE (Cont)
b. Loosen tube nut (5) and separate pump suction tube (6) from check body (7).
c. Cut pump suction tube (6) above ferrule (8) and nipple (9) and remove from reservoir tank (10).
d. Remove check valve washer (11), check valve tit (12), and check body (7) from strainer cup (13).
INSPECT
a. Inspect strainer cup, check body, nut, screw, and tube nut for damaged threads and corrosion. Replace as
required.
b. Inspect clamp, check valve tit, and check valve washer for damage. Replace as required.
INSTALL
Hypochlorite solution is toxic to skin and eyes. Avoid
repeated or prolonged contact.
Wear skin and eye
protection to prevent personal injury.
a. Install pump suction tube (6) in reservoir tank (10).
b. Install tube nut (5), ferrule (8), and nipple (9) on pump suction tube (6).
c. Install check body (7) and check valve tit (12) on strainer cup (13).
d. Install check valve washer (11), pump suction tube (6), and tube nut (5) on check body (7). Tighten tube nut
(5).
e. Install clamp (4), screw (3), nut (2), and reservoir tank cover (1).
END OF TASK
4-24