TM 55-1930-209-14&P-1
Table 6-2. Emergency Interior Lighting System Components
Component
Location
Function
Emergency lighting panel
ROWPU space on
Supplies power to
forward bulkhead
ROWPU space
near power panel 3
dayroom, workshop
and void emergency
fluorescent and red lights
18 fluorescent
6 in ROWPU space
Provides emergency
lights (Barge 1)
1 in dayroom
lighting in deckhouse
1 in workshop
and voids
19 fluorescent lights
1 in void 1
(Barges 2 and 3)
1 in void 2 port
1 in void 2 starboard
2 in void 3 port
2 in void 3 starboard
1 in void 4 port
1 in void 4 starboard
1 in void 5
4 incandescent red lights
2 in ROWPU space
Supplies lighting for
1 in workshop
night use in case
1 in dayroom
fluorescent lights must
be blacked out
4 emergency light
2 in ROWPU space by
Turns emergency lights
toggle switches
port and starboard
ON/OFF throughout barge
doors to weatherdeck.
1 on switchboard in
ROWPU space.
1 in dayroom by door to
weatherdeck
Green (Barge 1) or blue
On forward panel of
Indicates that emergency
(Barges 2 and 3)
switchboard above
power is available from
indicator light
emergency light toggle switch
battery bank
Controls/indicators
Figure
10A rotary snap switch
6-3
(labeled WORKSHOP LIGHTS)
30A 3-way rotary snap switch
6-4
(labeled DAYROOM LIGHTS)
Power panel 3 circuit breakers
6-5
Deck lighting panel circuit breakers
6-6
Void lighting panel circuit breakers
6-7
Emergency lighting panel circuit breakers
6-8