TM 55-1930-209-14&P-10
2-10
Shutdown procedures
2-10.1 Normal lighting
a.
Turn ROWPU space fluorescent lights OFF by opening circuit breaker 2P13-1 thru 2P13-4 on deck lighting
panel.
b.
Turn dayroom fluorescent lights OFF by operating either of the rotary snap switches in the dayroom or by
opening circuit breaker 2P13-6 on deck lighting panel.
c.
Turn workshop fluorescent lights OFF by operating rotary snap switch in workshop or by closing circuit breaker
2P13-5 on deck lighting panel.
d.
Turn fluorescent lights OFF in the voids by opening circuit breakers 3P13-1 thru 3P13-8 on void lighting panel.
2-10.2 Emergency lighting
To turn all emergency lights OFF (fluorescent and red), operate any of the four emergency light toggle switches,
circuit breakers, inverter, or inverter circuit breaker.
Section IV. Maintenance instructions
2-11
General
2-11.1 Maintenance concept
2-11.1.1
Unit level and Intermediate Direct Support and Intermediate General Support (IDS/IGS) maintenance on the
interior lighting system Is performed onboard by barge crewmembers whenever possible.
2-11.1.2
Any IDS/IGS maintenance beyond capability of crewmembers is provided by a shore-based area support
maintenance unit. This unit also determines if depot support maintenance is required.
2-11.1.3
Intermediate support maintenance is accomplished by replacement of components or major end items.
2-11.1.4
Unless other intermediate support procedures are directed, IDS/IGS maintenance normally is provided by
an Army Transportation Corps floating craft intermediate support maintenance unit serving terminal operating area.
Components to be disposed of are processed by this unit.
2-11.1.5
Maintenance Allocation Chart (MAC) Is In TM 55-1930-209-14&P-18. For maintenance of other equipment
onboard, consult appropriate manual.
2-11.2 Maintenance procedures. Maintenance instructions are contained in the following paragraphs: Appendix C,
Preventive maintenance checks and services; and paragraph 2-13, Troubleshooting.
2-12
Preventive maintenance checks and services. See TM 55-1930-209-14&P-10, Appendix C for preventive
maintenance checks and services for the lighting system. See TM 55-1930-209-14&P-19 for complete preventive
maintenance checks and services for all systems on the ROWPU Barge.
2-14