Krueger Crane Systems INC4699ColtRoad,Rockford,ILL,61109ABCTroubleShut-off but no lightCause1.Burned out fuse2Light bulb burned out3.Broken cableCorrectiveaction1. Check fuse and replace with20Afuse only2. Check light bulb and replace (12 VDC/24 VDC)3. Check cable: a.Measure voltage at control panel terminalNo.1 (hot+) No.2 (ground -)b.Measure voltage where wires are hooked upto the terminals of the crane power supplyc.Measure voltage at terminals No.5 (hot) andNo.2 (ground) leading to solenoidsd.Measure voltage at the solenoidsNote:If 12 VDC is on the power supply but not on terminal No.1 and No.2 replace cable.If 12 VDC is on No.5 and No.2 but not at the solenoid replace cable.Phone (815) 874-9402Telex 25-7498- 8