Section:
SP PUMPS
Page: 1 of 4
Date: March 30, 1984
SERVICE MANUAL
MOYNO® SP PUMPS
SERIES 356 & 367 MOTORIZED
MODELS 35651 & 36751
DESIGN FEATURES
Housing:
Cast iron
Pump Rotor:
AISI 416 stainless steel
Pump Stator: NBR
Seal-
NBR (Nitrile)
Motcr Shaft:
Mechanical (carbon/ceramic)
Motor:
3 phase; 1 HP, 208/2301460V for Series
356; 2 HP, 2301460 V for Series 367; 60
Hertz, 1725 rpm, totally enclosed
Note: Alternate elastomers available. Refer to Repair/
Conversion kit numbers, page 4
INSTALLATION
Mounting Position. Pump may be mounted in any
position. When mounting vertically, it is necessary to
keep bearings above seals to prevent possible seal
leakage into bearings Pre-Wetting. Prior to connecting
pump, wet pump elements and mechanical seal by
adding fluid to be pumped into suction and discharge
ports Turn pump over several times in a clockwise
direction to work fluid into pump elements Piping. Piping
to pump should be self-supporting to avoid excessive
strain on pump housings. See Table 1 for suction and
discharge port sizes of each pump model.
Use pipe "dope" or tape to facilitate disassembly and
to provide seal on pipe connections.
Electrical. Follow the wiring diagram on the motor
nameplate or inside the terminal box for the proper
connections. The wiring should be direct and conform to
local electrical codes Check power connections for
proper voltage. Voltage variations must not exceed +
10% of nameplate voltage. Motors do not have overload
protection.
To prevent damage to pump, pump rotation must be
clockwise when facing pump from motor end.
OPERATION
Self-Priming. With wetted pumping elements, the pump
Is capable of 25 ft. suction lift with pipe size equal to port
size. Be sure suction lines are air tight or pump will not
self prime.
DO NOT RUN DRY. Unit depends on liquid pumped for
lubrication. For proper lubrication, flow rate should be at
least 10% of rated capacity.
Moyno Is a registered trademark of Robbins & Myers,
Inc.
Pressure and Temperature Limits. See Table 1 for
maximum discharge pressure of each model Unit is
suitable for service at temperatures shown in Table 2.
Storage. Always drain pump for extended storage
periods by removing bottom drain plug. To drain Model
36751 remove suction housing bolts and loosen suction
housing
Caution: Suction pressure should never be greater
than discharge pressure.
Table 1. Pump Data
Pump Model
35651
36751
Suction Port (NPT)
1-1/2
2
Discharge Port (NPT)
1-1/4
1-1/4
Voltage Rating (VAC)
2301460
230/460
Discharge Pressure
(psig) (maximum)
50
50
NOTE: SSU= 5 x CP (approximate)
specific gravity
Table 2. Temperature Limits
Elastomer
Temperature Limits
*NBR
10-160F
*EPDM
100-210F
*FPM
10-240F
*NBR = Nitrile
EPDM = Ethylene-Propylene-Diene Terpolymer
FPM = Fluoroelastomer