TM 55-1930-209-14&P-15
2-8.3
Coffeemaker
a.
Remove cover, coffee basket and stem.
b.
Fill coffeemaker with cold water to desired level as listed in table below.
Water level, in cups
Amount of ground coffee. in cups
Strong
Mild
36
31/4
2
30
23/4
1 3/4
24
21/4
1 1/2
18
1 3/4
1 1/4
12
1 1/4
1
c.
Place stem in heating unit well and place coffee basket on stem.
d.
Fill coffee basket with coffee as indicated above. Do not brew less than 12 nor more than 36 cups.
e.
Replace cover and twist to lock in place.
f.
Plug cord into coffeemaker receptacle. Coffee will begin perking. When red light comes on, coffee is ready.
g.
Before serving coffee, remove cover, basket containing grounds, and stem. Replace cover only. Dispose of
coffee grounds. Clean and stow basket and stem.
h.
Coffee will remain at serving temperature as long as the coffeemaker is plugged in. When about 3 cups of coffee
remain In coffeemaker, unplug it.
2-8.4
Refrigerator. Refrigerator automatically starts when it is plugged into a receptacle. Internal temperatures are
preset at the factory and are indicated on the top front of the refrigerator. To turn refrigerator off, unplug it.
2-8.5
Range hood. Use ON/OFF switches on front panel to operate exhaust fan and light.
2-9
Shutdown procedures
a.
Unplug coffeemaker and hotplate. Perform after operation services.
b.
Under normal operations, drinking fountain and refrigerator are not turned off unless barge is to be placed in long-
term storage.
2-9.1
Emergency shutdown
2-9.1.1 General. The barge has two emergency shutdown modes. One mode (system shutdown) shuts down individual
systems such as the ventilation system or a diesel high pressure pump, and the other mode (total shutdown) shuts down
all barge operating systems.
Both systems are operated by pushing a red button protected by a metal guard. On system shutdowns, this button
shuts off either fuel or electrical power to that system only. On total shutdown, this button shuts off all fuel and electrical
power to all operating systems.
Emergency system shutdown red buttons are on the ROWPU space starboard bulkhead just aft of the personnel
door. These seven emergency system shutoff buttons (Figure 2-3) control shore power, ventilation systems, ROWPU 1
diesel high pressure (HP) pump, ROWPU 2 diesel HP pump, ship auxiliary generator (SAG), ship service generator 2
(SSG2), and ship service generator 1 (SSG1).
2-6