MOTOR PROTECTION (Continued)
2. THERMAL MOTOR PROTECTION is provided by a pilot duty, automatic reset, internal thermostat located in the
motor windings. The thermostat relay contacts are rated at 240 VA and care must be taken that this rating is not
exceeded. Thermostat connections are made at terminals #8 and #9 on the compressor terminal block in the
terminal box.*
CAUTION
(* Please note that the relay contact as defined above are rated at 240 Volt-Amperes and
should not be considered volts only).