TM 55-1930-209-14&P-2
Table 3-2. Seawater System Valves (continued)
Figure 1-3
Label Identification
Type:
Callout
Location
and Valve Function
1/4-in gate valve
SW35
Void 2 port - In sea-
COOLING WATER STRAINER
water supply line
PRESSURE IN: Allows pressure
between seachest and
reading on supply side
cooling water strainer
of cooling water strainer
1/4-in gate valve
SW36
Void 2 port - In
COOLING WATER STRAINER
seawater supply line
PRESSURE OUT: Allows pressure
between cooling water
reading on discharge side of
strainer and cooling pump
cooling water strainer
4-in gate valve
SW37
Void 4 port - In sea-
GENERATOR COOLING
water supply line
SEACHEST TO STRAINER:
between seachest and
Allows flow from sea-
strainer
chest to strainer and isolates
strainer
2-in gate valve
SW38
Void 4 port - On input
STRAINER TO GENERA-
side of generator 1
TOR 1 COOLING: Allows
cooling line
cooling flow to generator 1 and
isolates strainer
2-in globe valve
SW39
Void 4 port - On
GENERATOR 1 COOLING
discharge side of
TO OVERBOARD: Allows cooling
generator cooling line
flow from generator and isolates
generator from overboard
discharge
2-in gate valve
SW40
Void 4 starboard - On
STRAINER TO GENERATOR
input side of generator 2
2 COOLING: Allows cooling
cooling line
flow to generator 2 and isolates
strainer
2-in globe valve
SW41
Void 4 starboard - On
GENERATOR 2 COOLING
discharge side of
TO OVERBOARD: Allows cooling
generator cooling line
flow from generator and isolates
generator from overboard
discharge
1 1/4-in gate valve
SW42
Void 4 starboard - On
STRAINER TO 20 kW
input side of 20 kW
GENERATOR COOLING:
generator cooling
Allows cooling flow to 20 kW
generator and isolates strainer
1 1/4-in globe valve
SW43
Void 4 starboard - On
20 kW GENERATOR COOL-
discharge side of 20 kW
ING TO OVERBOARD: Allows
generator cooling line
cooling flow from generator and
isolates generator from overboard
discharge
2-in gate valve
SW44
ROWPU space - in cooling
GENERATOR COOLING SEA-
water seachest vent line
CHEST VENT: Allows sea-
chest venting
3-9