TM 55-1930-209-14&P-2
Table C-1. Preventive Maintenance Checks and Services for Seawater System (Continued)
B - Before
D - During
A - After
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
S - Semiannually
A - Annually
ITEM
PROCEDURES
EQUIPMENT
ITEM
INTERVAL
TO BE
CHECK FOR AND HAVE
IS NOT READY/
NO.
INSPECTED
REPAIRED OR ADJUSTED
AVAILABLE IF
B D A D W M Q S A
AS NECESSARY
d. Check for loose or missing securements
Securements
and fasteners. Tighten and replace as
and/or fasteners
necessary.
loose or missing.
2
Wiring
a.
Check wiring for loose connections and
Cables frayed.
frayed cables. Secure as necessary.
Repair or replace damaged cables using
insulated tools
b. Visually check wiring for loose connec-
Connections
tions. If sparks are visible, immediately
loose.
stop operation and report to shift leader
or bargemaster.
3
Seawater
a. Ensure that seawater strainer baskets
Strainer
(void 2 port and starboard) are dean and
properly installed.
b. Change flow, remove and clean, or
replace as follows.
1) To change flow.
Loosen diverter plug locking flange
by turning locking T-bolt handle/
handlewheel counterclockwise.
Turn handle toward clean basket
until it stops.
CAUTION
Never operate strainer with diverter plug
unseated. Sediment may collect
under plug and prevent a tight seal
causing damage to equipment.
Tighten locking flange by turning
locking T-bolt handle/handlewheel
clockwise to seat diverter plug. Do
not overtighten.
2) To remove and clean seawater
basket:
Loosen yoke screw until yoke
swings free.
C-4