TM 55-1930-209-14& P-5
Table 3-2. Drinking Water System Valves
Figures 1-2
and 1-3
Label Identification
Type
Callout
Location
and Valve Function
3-in globe valve
DW1
Void 3 port (Barge 1)
STORAGE TANK 1 FILL: Allows
starboard (Barges 2 & 3)
chlorine treated product water
- in storage tank 1 fill
from ROWPU's to flow into tank
line on top of tank
1 and isolates tank
3-in globe valve
DW2
Void 3 starboard (Barge 1)
STORAGE TANK 2 FILL Allows
port (Barges 2 & 3) - in
Chlorine treated product water
storage tank 2 fill line on
from ROWPU's to flow into tank
top of tank
2 and Isolates tank
3-in globe valve
DW3
Void 3 port (Barge 1)
STORAGE TANK 3 FILL: Allows
starboard (Barges 2 & 3) -
Chlorine treated product water
In storage tank 3 fill line
from ROWPU's to flow into tank
on top of tank
3 and Isolates tank
3-in globe valve
DW4
Void 3 starboard (Barge 1)
STORAGE TANK 4 FILL Allows
port (Barges 2 & 3) -
chlorine treated product water
in storage tank 4 fill line
from ROWPU's to flow into tank
on top of tank
4 and Isolates tank
1/2-in globe valve
DW5
Dayroom - In water
DAYROOM SUPPLY Allows
line between pressure
drinking water to flow to and
set and drinking
Isolates drinking fountain and
fountain
sink
3/8-in globe valve
DW5A
Dayroom - In water
DRINKING FOUNTAIN SUPPLY
(Barges 2 and
line to fountain
Allows drinking water to flow to
3 only)
isolates drinking fountain
4-in gate valve
DW6
Void 3 port (Barge 1)
STORAGE TANK 1 DRAIN
starboard (Barges 2 & 3) -
Allows drinking water to drain
in storage tank 1 drain line
from tank 1 and Isolates tank
near tank
4-in gate valve
DW7
Void 3 starboard (Barge 1)
STORAGE TANK 2 DRAIN
port (Barges 2 & 3) -
Allows drinking water to drain
in storage tank 2 drain line
from tank 2 and Isolates tank
near tank
4-in gate valve
DW8
Void 3 port (Barge 1)
STORAGE TANK 3 DRAIN
starboard (Barges 2 & 3)-
Allows drinking water to drain
In storage tank 3 drain line
from tank 3 and isolates tank
near tank
4-in gate valve
DW9
Void 3 starboard (Barge 1)
STORAGE TANK 4 DRAIN gate
(Barges 2 & 3) - in storage
Allows drinking water to drain
tank 4 drain line near tank
from tank 4 and Isolates tank
2-in
DW10
Void 3 starboard
STORAGE TANK DRAIN TO
globe valve
- under deck in
BILGE. Allows drainage of
(Barges 2 and
storage tank drain
drinking water from storage
3 only)
line near fuel pump
tank(s) to bilge
1-1/4 in gate valve
DW11
Void 3 port - in
PRESSURE SET SUPPLY
pressure set inlet
Allows drinking water to flow to
line between main
pressure set and Isolates
drinking water supply
pressure set
line and pressure set
4-in ball valve (3-way)
DW12
Void 3 port - In
DISCHARGE PUMP I SUPPLY
discharge pump
Allows pump to drain drinking
suction line near
water from storage tank(s)
pump 1
3-2