Installing Replacement Filter Elements For Two Stage Air Cleaner
1.
Remove the cover.
Cleaning Air Cleaner Elements
When using pressure air, wear face shield and protective
clothing. Maximum air pressure for cleaning purposes
must be 205 kPa (30 psi).
CAUTION
When cleaning with pressure water, use 280 kPa (40
psi) maximum pressure to prevent element damage.
Pressure Air - 205 kPa (30 psi) Maximum
1.
Direct air inside along length of pleats.
2.
Remove the inner cover and filter element. In cold
weather, a stuck inner cover may be removed by
warming the air cleaner cover to 21-24C (70-75°F).
3.
Clean all parts of the air cleaner.
4.
Inspect the replacement element for damage and
cleanliness.
5.
Install a clean undamaged element, inner cover, and
wing nut. Tighten the wing nut.
6.
Install the cover.
CAUTION
Do not clean elements by bumping or tapping them
on hard objects.
Inspect an element after cleaning. Do not use an
element with damaged pleats, gaskets or seals.
Have spare elements on hand to use when cleaning
used ones.
Dry type air cleaner elements can be cleaned with either
pressure air, water or detergent.
2.
Direct air outside along length of pleats. Direct
air inside along length of pleats. Inspect.