ELECTRIC SHUTOFF SYSTEM
TROUBLESHOOTING
TROUBLESHOOTING PROCEDURE (CRANK TERMINATE)
NOTE A: DO NOT LEAVE STARTER MOTOR ENGAGED WITH THE
ENGINE RUNNING.
To perform test measurements use one of the three methods
that follows to disengage the starter motor.
1.
Connect speed switch terminal 10 to terminal 11 to disengage
the starter motor.
2.
Use a toggle switch to control the magnetic switch. Connect
toggle switch in series with the magnetic switch coil lead.
3.
Connect a starter tester that has a manual disconnect control.
NOTE B: Make reference to the SPEED SPECIFICATION CHART for
the correct overspeed or crank terminate speed setting.
72