TM 55-2090-201-14&P
3-6.
PRESSURE GAUGES, MOUNTING BRACKET, LEGEND AND IDENTIFICATION
PLATES, TYPE A and B SEPARATORS (Continued).
LOCATION
ITEM
ACTION
R E M A R K S
Cleaning
Cleaning solvent Fed. Spec. P-D-680 used to clean
parts is potentially dangerous to personnel and
property.
Avoid repeated and prolonged skin contact.
Do not use near open flame or excessive heat.
Flash point of solvent is 100° - 138°F (38° - 59°C).
a. Using a mild detergent,
water and a clean cloth,
wipe gauges clean.
b. Clean bracket with a clean
cloth dampened in cleaning
solvent P-D-680 and dry
thoroughly.
Repair
Replace defective part with
serviceable-like item.
Installation
5.
Mounting
a. Position mounting bracket
bracket
(16) on control panel (11).
b. Use flat washer (15), bolt
(14), lockwasher (13) and
nut (12) to fasten bracket
(16) to control panel (11).
6.
7.
Legend
Press in place if replaced.
Self-adhesive.
and iden-
tification
plates
(7, 8, 9
and 10)
Pressure
a.
Insert pressure gauge (6)
gauge
thru opening in mounting
bracket (16).
3-48