TM 55-2090-201-14&P
3-49.
MINI-PROBE, TYPE A AND B SEPARATORS (Continued).
L O C A T I O N
ITEM
A C T I O N
R E M A R K S
Test Procedure
Meter
Reading
(VDC)
Test Conditions
Remarks
light/button
(6) thereby
grounding the
mini-probe
test terminal. 24
ton (6) to
illuminate, the
first (prefil-
ter) stage
solenoid opera-
ted oil dis-
charge valve
(7) to open,
the solenoid
operated water
discharge
valve (8) to
close, and
overboard dis-
charge light
(9) to go out.
Replace the
mini-probe
(5) if a 24±5
VDC reading-is
not obtained.
C. Connect the
test meter
leads first
to contacts
5 and 9, and
depress the
first stage
(prefilter)
oil dump
light/button
(6).
Next,
24
connect the
test meter
leads to con-
tacts 7 and
9 and again
depress the
first stage
C. A 24 VDC read-
out between
contacts 5 and
9 indicates the
first stage
(prefilter oil
discharge valve
(7) and the
first stage
(prefilter)
dump light/but-
ton (6) are re-
ceiving a sig-
nal from mini-
probe (5) and
that the print-
ed circuit
board is func-
3-374