TM 55-2090-201-14&P
3-49.
MINI-PROBE,
TYPE A AND B SEPARATORS (Continued).
L O C A T I O N
ITEM
A C T I O N
R E M A R K S
Meter
Reading
Test Procedure
(VDC)
Test Conditions
Remarks
grounds the
mini-probe's
test terminal. 24
second stage
solenoid operat-
ed oil discharge
valve (11) will
open. The sole-
noid operated
water discharge
valve (8) to
close, and the
overboard dis-
charge light (9)
will go out. Re-
place the mini-
probe (5) if a
24 ± 5 VDC
reading is not
obtained.
C. Connect the
test meter
leads first
to contacts
6 and 9 and
depress the
second stage
oil dump
light/button
(10).
Con-
24
nect the test
meter leads
to contacts
7 and 9. De-
press the
second stage
oil dump
light/button
0
(10).
C. A 24 VDC read-
out between con-
tacts 6 and 9
indicates second
stage oil dis-
charge valve
(11) and second
stage oil dump
light/button
(10) are receiv-
ing a signal
from the mini-
probe (5). The
printed circuit
board is func-
tioning proper-
lY.
A zero read-
out between con-
tacts 7 and 9
indicates the
water discharge
valve (8) and
3-390