TM 55-2090-201-14&P
4-9.
PRESSURE GAUGES, MOUNTING BRACKET, IDENTIFICATION AND LEGEND
PLATES, TYPE C and D SEPARATORS (Continued).
LOCATION
ITEM
A C T I O N
R E M A R K S
Cleaning solvent Fed. Spec. PD-680 used to clean
parts is potentially dangerous to personnel and
property.
Avoid repeated or prolonged skin con-
tact. Do not use near open flame or excessive heat.
Flash point of solvent is 100°-138°F (38°-59°C).
Cleaning
a. Using a mild detergent,
water and clean cloth,
wipe gauges clean.
b. Clean bracket with a clean
cloth dampened in cleaning
solvent PD-680 and dry
thoroughly.
Replace defective part with
a. Serviceable-like item.
Repair
Installation
Mounting a. Position mounting bracket
bracket
(15) on control panel (10).
b. Use flatwasher (14), bolt
(13), lockwasher (12), and
nut (11), to fasten bracket
(15) to control panel (10).
6.
Legend
and iden-
tification
plates (7,
8 and 9)
Press in place if replaced.
Self adhesive.
4-12