TM 55-2090-201-14&P
4-38.
MOUNTING FRAME -TYPE A AND B SEPARATORS (Continued).
L O C A T I O N
ITEM
A C T I O N
R E M A R K S
Cleaning
Cleaning solvent Fed. Spec. PD-680 used to clean
parts is potentially dangerous to personnel and
property.
Avoid repeated or prolonged skin contact.
Do not use near open flame or excessive heat.Flash
point of solvent is 100° - 138°F (38° - 59°C).
Inspection
Inspect mounting frame for
cracks, distortion or broken
welds.
Repair
Repair cracks or broken
welds using approved weld-
ing practices.
Grind smooth.
Clean, prime and paint dis-
turbed areas.
Installation
NOTE
Attach a suitable sling around the motor and
separators.
Using a hoist, place assembled
separators into position on mounting frame.
8.
9.
Separ-
Install, using washers (10),
ators
bolts (9), washers (8) and
(11)
nuts (7).
Motor
Install, using washers (4),
(5)
screws (3), washers (2) and
nuts (1).
4-206