TM 55-2090-201-14&P
6-13.
OIL DISCHARGE VALVES, ELECTRICALLY OPERATED [1ST (PREFILTER)
AND SECOND STAGE ONLY], TYPE A AND B SEPARATORS (Continued).
L O C A T I O N
I T E M
A C T I O N
R E M A R K S
1.
2.
Diaphragm Subassembly
Core Spring
3.
Bonnet Gasket
4.
Body Gasket
5.
Body
Cleaning solvent Fed. Spec. PD-680 used to clean
parts is potentially dangerous to personnel and
property.
Avoid repeated or prolonged skin contact.
Do not use near open flame or excessive heat.
Flash
point of solvent is 100o - 138°F (38o - 59oC)
a. Clean metal parts of
valve assembly in cleaning
solvent Fed. Spec. PD-680
and dry thoroughly.
b. Clean diaphragm and coil
using a clean cloth.
6-21