TM 55-2090-201-14&P
3-3.
OPERATORS TROUBLESHOOTING PROCEDURES (Continued).
Table 3-4.
Test Procedures for Electrical and Electronic Components,
Type A Separators (Continued).
Test Procedure
Meter
Reading
(VDC)
Test Conditions
Remarks
2.
(Continued)
A malfunction in
the printed cir-
cuit board is in-
dicated when the
mini-probe gene-
rated signal is
not relayed to
the solenoid
valve.
Refer to para-
graph 3-49 for
mini-probe
replacement.
A. Connect the
test meter
leads to
terminal
contacts 1
and 8 on
Terminal
Board TB1
O
B. Connect the
test meter
leads to ter-
minal con-
tacts 1 and
3.
Depress
the No. 1
(prefilter)
oil dump
light/button
(7).
This
grounds the
mini-probe
test terminal. 24
A. Replace the mini-
probe (5) if a
zero reading is
not obtained on
the test meter.
Refer to para-
graph 3-49 for
replacement of
mini-probe.
B. Depressing the
No.
1 oil dump
light/button (7)
will cause the
mini-probe to
generate a
signal.
This lights the
first stage (pre-
filter) oil dump
light (7).
The
first stage (pre-
filter) solenoid
operated oil dis-
charge valve (8)
opens.
The sole-
noid operated
3-16