TM 10-4610-229-10
2-4.
ASSEMBLY AND PREPARATION FOR USE (CONT)
7
Remove two bolts, two nuts, and two end clamp halves. Set aside for installation.
8
Gently work end cap assembly back and forth to remove from pressure tube. Set aside in a
clean place.
9
Using garden hose, rinse out inside of tubes.
10
Remove brine seal from reverse osmosis membrane element. Inspect seal for damage. If
damaged, notify your supervisor. Lightly coat seal with silicone lubricant (item 5, appendix D).
Install seal on element.
NOTE
Make sure that lip of brine seal faces other (product water) end of pressure tube.
11
Place lead end of element in feedwater end of pressure tube. Check to see that brine seal is
properly in place.
2-88