Figure  2-61.  Carbon  Monoxide  Monitor  (sheet  1 of 3)

TM-10-4610-232-34 Water Purification Unit Reverse Osmosis 3 000 GPH Trailer Mounted Flatbed Cargo 22-1/2 Ton 8 Wheel Tandem Model No. WTA-060 Manual
Page Navigation
  204    205    206    207    208  209  210    211    212    213    214  
TM    10-4610-232-34 2-56.   CARBON   MONOXIDE   MONITOR.   This   task   covers: a. Testing. b.  Adjust. c.  Removal. d.  Disassembly. e.  Repair. f.  Reassembly. g.  Installation. INITIAL   SETUP. Tools,  see  TM  10-4610-232-12,  Appx  B. Equipment  Condition: Sec Ill, Ref Code (No.) Power supplied to CO monitor. Tool Kit, General Mechanics Automotive (1) Calibration Kit, CO Monitor (17) General Safety Instructions: Materials/Parts: WARNING Suitable  Tags Gaskets    (TM    10-4610-232-24P) Lockwashers    (TM    10-4610-232-24P) Preformed   Packing   (TM   10-4610-232-24P) Washers   (TM   10-4610-232-24P) Observe specific Warnings in text. WARNING Inhalation of carbon monoxide can cause serious illness or death. TESTING. a. Turn the screw (1, Figure 2-61, sheet 1 ) 1 /4 turn clockwise and open the door. b. Turn the power switch (2) momentarily to off, then on. Verify that the display (3) momentarily lights and display 8.8.8 and the ALARM 2 indicator (4) and the SYSTEM OK indicator (5) momentarily light. c. If, after performing the above display test, the green SYSTEM OK indicator (5) goes out and the main display (3) reads P-1 or P-2, refer to adjusting procedure below. d. If the audible alarm goes on, press the alarm reset button (6) located on the bottom of the case. e. Press the ALARM 1 button (7). The main display (3) should read 25. If display does not read 25, refer to adjusting procedure below. f. Push ALARM 2 button (8). The main display (3) should read 50. If display does not read 50, refer to the following adjusting procedure below. ADJUST. a. b. c. d. e. Install sensor zero cap (9) into the sensor (1O) inlet. Wait approximately 1-1/2 minutes or until a stable reading is displayed. NOTE Pot turns clockwise to increase reading. Adjust the zero pot (11 ) for a reading of O on the main display (3). Remove the zero cap (9) and install the calibration adapter (12). Attach flow control (13) to calibration gas tank. f. Attach tubing (14) to calibration adapter (12) and flow control (13). 2-191







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.