TM 10-4610-239-10
TM 08580B-10/1
Table 3-1. (Army) Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
BRAKES ON ONE SIDE ENGAGE BEFORE THOSE ON THE OTHER SIDE.
Step 1.
Check the movement of the slack adjusters to see if they are out of adjustment.
Notify unit maintenance.
Step 2.
Check the brake camshaft movement to see if there is any restriction on movement.
Notify unit maintenance.
4.
BRAKES SLIP
Step 1
Check brake adjustment, and inspect for defective brake assembly parts.
Notify unit maintenance to adjust brakes or replace defective parts.
Table 3-2. Troubleshooting (ROWPU)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
ANY BLUE PUMP LAMP GOES OFF.
Step 1. Check to see if associated pump is operating. For R.O. pumps, see if sheave is turning; for other pumps, rest
hand lightly on the motor casing to feel for motor vibrations.
a. If pump is not operating, check and reset circuit breaker (fig. 2-4, sheet 3 of 3) and then
immediately try to restart pump. Do so only one time.
b. If pump fails to start, notify unit maintenance.
c. Shut down ROWPU in normal manner (para. 2-31) except when only one raw water pump fails
or distribution pump fails. In these two cases the ROWPU can still be operated.
3-4