REPLACE PUMPHEAD ASSEMBLY
REPLACE OUTLET BALL VALVE ASSEMBLY

TM-10-4610-244-13 Hypochlorination Unit NSN 4610-01-364-4485 Model AHY001 Manual
Page Navigation
  37    38    39    40    41  42  43    44    45    46    47  
TM 10-4610-244-13 TM 09476B-13/1 4-15.  REPLACE PUMPHEAD ASSEMBLY (Cont'd). WARNING Calcium hypochlorite solution Is caustic and can cause severe chemical burns.  To avoid injury: •-Wear required protective gear. •-If  hypochlorite  solution  comes  in  contact  with  skin  or  eyes,  flush  immediately  with  large amounts of water and seek medical attention. a. REMOVAL (1) Remove two screws (1) (2) Remove pumphead assembly (2) (3) Remove gasket (3), inspect for cracks, deformation, or deterioration If any, discard b. INSTALLATION (1) Position gasket (3) on upper housing assembly (4). (2) Position pumphead assembly (2) on gasket (3). (3) Install 2 screws (1). 4-15