TM 3-4230-237-10
0016 00
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued
Table 1. Before Operation PMCS for M12A1 DED Decontaminating Apparatus - Continued.
33
34
35
Procedure
Not Fully
Item
Interval
Man
Item to be
Mission
No.
Hour
Checked/
Capable If:
Serviced
a. Inspect to see that all cables and hoses are properly
Water Heater
BEFORE
33
stored in storage compartment.
b. Inspect for loose or missing nuts or bolts. Tighten
hardware when necessary.
Identification
c. Check that all decals, stencils, and identification
plates are missing
plates are legible.
and TM is
missing.
Electrical wire
d. Check that electrical wires are properly secured
clamp is missing.
above boiler and not touching boiler.
a. Inspect control box for broken, missing, or loose
Control Box
BEFORE
34
parts. Tighten as necessary.
Assembly
b. Inspect to see that the glass in the fuel, water, and
temperature gages is not broken.
c. Check that controls and instruments are in good
condition.
Lines are kinked.
Check all the fabricated lines for signs of kinks and
All Fabricated
BEFORE
35
sharp bends.
Lines
0016 00-18