TM 3-4230-237-10
0016 00
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued
Table 1. Before Operation PMCS for M12A1 DED Decontaminating Apparatus - Continued.
36
Procedure
Not Fully
Item
Interval
Man
Item to be
Mission
No.
Hour
Checked/
Capable If:
Serviced
Water Heater
(Cont)
Fuel filter cracked
36
BEFORE
Fuel Filter
a. Inspect burner fuel filter (1) for cracks or leaks.
or leaking.
Unable to drain
b. Inspect for accumulation of dirt or water in plastic
contaminants from
filter.
follows:
(1) Position container under drain plug (3).
(2) Loosen drain plug (3). Allow fuel to drain into
(3) Tighten drain plug (3) and check for leakage.
Drain plug
c. Check for loose/missing drain plug (3). Tighten if
missing.
loose.
1
2
3
0016 00-19