TM 3-4230-237-10
0019 00
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued
Table 1. Quarterly and Annual PMCS for M12A1 DED Decontaminating Apparatus - Continued.
4
5
3
Procedure
Not Fully
Item
Interval
Man
Item to be
No.
Hour
Checked/
Mission
Capable If:
Serviced
a. Inspect pump unit for rust or corrosion.
Pump Unit
QUARTERLY
3
Remove any rust or corrosion with wire brush
b. Inspect pump unit surfaces for cracks, dents,
damage, and deformation.
(1) Clean the exterior of the pump unit with
hot, soapy water then rinse with clear water.
(2) Lubricate according to Lubrication
c. Inspect canvas cover to see that all buckles,
snaps, and straps are in good condition and not
corroded or damaged. If cover is unserviceable
and needs to be replaced, notify Unit Maintenance.
a. Wash panels with hot soapy water and rinse
Cover Panels
QUARTERLY
4
with clear water. Remove any rust with wire brush
Check that the assemblies can be removed easily
Clevis and
QUARTERLY
5
from the frame and are not damaged. Check for
Eyebolt
damaged threads. Make sure the clevis and eyebolt
Assemblies
assemblies are securely in place and are free of
burrs, and cracks.
0019 00-3