TM 3-4230-237-10
0019 00
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) Continued
Table 1. Quarterly and Annual PMCS for M12A1 DED Decontaminating Apparatus - Continued.
11
10
Procedure
Not Fully
Item
Interval
Man
Item to be
Mission
No.
Hour
Checked/
Capable If:
Serviced
Both discharge
QUARTERLY
Discharge
a. Inspect discharge hoses for leaks, breaks, or
10
hoses leak
Hose
other damage.
continuously.
Assemblies
WARNING
Fire and explosion danger exist
when solvent cleaning
compound is used. Make sure
that equipment is dry before
operations begin.
b. Flush hoses with hot water. Wash exterior of
discharge hoses with hot, soapy water. Dry all
parts thoroughly. Clean metal parts with a cloth
required.
a. Inspect the eductor hose for leaks or breaks.
11
QUARTERLY
Eductor Hose
Eductor hose
Assembly
leaks.
b. Make sure hose clamps are tight.
0019 00-6