TM 5-4610-223-12
4-60.
TWIST-LOW RECEPTACLE CONNECTORS, 110 VOLT.
a.
Removal.
(1)
Disconnect male connectors (2, fig. 3-19) from receptacles (1).
(2)
Remove the screws (4) and remove cover (1, fig. 4-47) and gasket (2).
(3)
Remove two screws (3) securing receptacle (4) to junction box (5) and pull receptacle from box.
1.
Cover
5.
Junction box
2.
Gasket
6.
Terminal screw
3.
Screw
7.
Wires
4.
Receptacle connector
Figure 4-47. Twist-Lock Receptacle Connector, Removal and Installation.
(4)
Loosen terminal screws (6) and tag and disconnect wires (7) from receptacle (4).
b.
Replace. Replace an unserviceable receptacle connector.
4-102