PRODUCT PIPELINE #4 February 22, 1982 Page 2 8. Install retaining ring in groove on spool stem. 9. Re-install  spool  assembly  in  the  controller  housing  and  repeat  steps  1  through  8  on  the  other  spool assembly(s) in the controller. NOTE The  shims  installed  to  set  the  start  pressure  also  add  the  same  amount  of  pressure  to  the maximum pressure of the spring range. (Example: A 0-200 PSI spring with a start pressure of 25 PSI would be a pressure control range of 25-225 PSI). Doug Van Erem Applications Engineer ss Attachments - Chart Drawing