TM 10-4610-215-10
TM 08580A-10/1
NOTE
If driving gets too hard, soak the earth and try driving rod until 8 feet of rod is in
the ground. If this does not work initially, continue alternately soaking ground
and driving rod. If unable to get 8 feet of rod into the soil, then keep soil moist
around the rod for the duration of the operation.
ac. Unwind the power cables of each pump. Pull the cables to the ROWPU junction box and unscrew
the covers of the connectors. Attach pump cables to the connectors shown in fig. 238. Plug the power cable from
the power source into J1, if not already installed.
Figure 2-35. Junction Box
2-23.
INITIAL ADJUSTMENTS AND CHECKS.
a. Drain Valves. Close all drain valves. Drain valves must remain closed at all times during operation.
NOTE
You will find all seven drain valves to the left front of the ROWPU as shown.
2-49