TM 10-4610-215-24
TM 08580A-24/2
(6) Move motor into shop.
(7) Remove pump from motor in accordance with paragraphs 3-34 or 3-36.
(8) Remove four screws (1) from conduit box (5) (figure 3-5) gasket (3), and conduit box cover (2) and
discard gasket (3).
(9) Remove three bolts (4) from motor casing (25), gasket (6), and conduit box (5) and discard gasket (6).
(10) Remove three screws (7) from fan-end plate (13) and fan cover (8).
(11) Remove fan cover (8) from fan-end plate (13).
(12) Loosen set screw (9) on fan-locking hub (10) and remove fan-locking hub (10) from rotor shaft (18).
(13) Remove fan (11) from rotor shaft (18).
NOTE
Mark fan-end plate, pump-end plate, and motor casing with
matching pump pricks to assure proper alignment during
reassembly.
(14) Remove four through-bolts (12) and nuts (14) from pump-end plate (16) and fan-end plate (13).
(15) Remove fan-end plate (13) from motor casing (25).
(16) Remove wavy washer (15) and shim (19) from rotor shaft (18).
(17) Using a bearing puller/press, remove fan end bearing (24) from rotor shaft (18).
CAUTION
Motor casing wiring can be snagged or broken by rotor shaft.
Take care not to damage wires when removing pum-end plate
and rotor shaft.
(18) Remove pump-end plate (16), with rotor shaft (18) attached, from motor casing (25).
(19) Remove two screws (17) from bearing retainer plate (22) and pump-end plate (16).
3-17