TM 104610-215-24TM 08580A-24/2n. ReconditioningCycleLengthAdjustment.WARNING(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)ELECTRICAL HIGH VOLTAGEElectrical high voltage can cause serious injury or death. Sometests performed in testing require power to be connected. Alwaystake proper measures to ensure personal safety.Depress latch (2) figure 3-18, sheet 1 of 2) and remove timer mechanism (17) from timer case (1).Loosen setscrew (33), but do not remove.Position black cam (28) to read 0 minutes.Position second cam (30) the desired minutes away from 0 minutes.Position brine refill dial (5) (figure 3–20, sheet 2 of 2) to desired time for second backwash cycle.Position third cam (30) (figure 3–1 8, sheet 1 of 2) to desired time for the OFF cycle.Position fourth cam (31) to desired time for purge cycle.Tighten cam setscrew (33) when all adjustments have been made.Rotate extra reconditioning knob (7) (figure 3–20, sheet 2 of 2) to IDLE position.Position pilot valve controller cam (1) (figure 3–20, sheet 1 of 2) to the service (SR) position.Install timer mechanism (8) (figure 3–20, sheet 2 of 2) in case.Run tests required to assure proper adjustments have been made.3-21. BACKWASH TIMER (SOLID STATE).a. General. The backwash timer automatically starts and ends the different stages of the backwash cycle ofthe multimedia filter. Each stage of the cycle time can be adjusted to suit a wide range of water types andoperating conditions. This paragraph describes the disassembly, cleaning, inspection, repair, and reassembly ofthe solid state timer. Refer to (figure 3–21 ) for schematic.3 - 96