TM 10-4610-215-24
TM 08580A-24/2
(7) Remove four handles (8).
(8) Remove four panel nuts (9), one from each valve, and remove valve assembly (10) from panel.
(9) Remove four bolts (11) and four lockwashers (12) from base of two vertical supports (13) for chemical
feed pump valves as shown in (figure 3-33).
(10) Remove two vertical supports (13).
c. Removal. (Figure 3-34) (USMC)
(6).
(6).
NOTE
Tag all plastic hoses before removal.
(1) Loosen twelve hose clamps (2) and remove hoses (1) from valves (10).
NOTE
Set control knobs to zero (0).
(2) Loosen setscrew (17) on control cable (18) and remove control cable (18) from control knobs (5).
(3) Remove three screws (3) and washers (4) from each of the control knobs (5) and remove from frame
(4) Remove setscrews (7) from handles (8) and remove handles (8) from valves (10).
(5) Remove panel nuts (9) and valves (10) from frame (6).
(6) Remove nuts (12), washers (14), and screws (13) from vertical supports (11) and remove upper frame
(7) Remove bolts (15) and lockwashers (16) from vertical supports (11).
(8) Remove vertical supports (11).
d. Cleaning.
(1) Clean threads of nuts and bolts, and apply a light coat of preservative spray oil.
(2) Wash valve mounting panel and two vertical supports with brush and mild detergent.
(3) Wash valve handles and serviceable valves in a mild detergent solution.
3-141