(7) Insert four bolts (5) through valve mounting panel (6) and two supports (1 3).
(8) Install four lockwashers (4) and four nuts (3) on bolts (5).
(9) Install twelve marked plastic tubes (1) and twelve hose clamps (2) on nipples of valves (10).
h. Installation. (Figure 3-34) (USMC)
(1) Attach vertical supports (11) to ROWPU frame using bolts (15) and lockwashers (16).
(2) Position upper frame (6) on vertical supports and install using screws (13), washers (14), and nuts
(12).
(3) Position valves (10) on upper frame (6) and secure using panel nuts (9).
(4) Install handles (8) on valves (10) using setscrews (7).
NOTE
Check that knobs are set at zero (0) before installing control
knobs.
(5) Install control knobs (5) on upper frame (6) using screws (3) and washers (4).
(6) Attach control cables (18) to control knobs (5) with set screws (17).
(7) Attach twelve marked hoses (1) to valves (10) and secure using hose clamps (2).
(8) Remove tags.
335. RAW WATER PUMP.
a. General. This paragraph describes removal, inspection, cleaning, and reassembly of the raw water pump.
b. Removal. (Figure 3-35)
(1) If necessary, see paragraph 2-43 to remove raw water pump from frame.
WARNING
Objects blown by compressed air can cause serious eye injury.
Always wear protective goggles when using compressed air.
3-144