TM 10-4610-229-10
2-7. REVERSE OSMOSIS MEMBRANES CLEANING (CONT)
15
Apply thin coat of silicone lubricant (item 5, appendix D) to gasket lips and outside of gasket.
16
Place gasket over end of connection C-8, being sure it doesn't overhang end of connection.
17
Aline end of brine discharge pipe with connection C-8. Slide gasket to center position between connection C-8
groove and pipe groove. No portion of gasket should overhang grooves.
18
Place grooved pipe coupling halves over gasket. Make sure grooved pipe coupling half keys are in grooves on
connection C-8 and pipe.
19
Install two bolts. Place nuts on bolts and hand-tighten.
2-8. SHUTDOWN
1
Push in high pressure pump engine throttle lock button. Slowly push in throttle until engine runs at low idle.
2-130