TM 10-4610-229-24NOTES:1. Identify correct wire and terminals.2. Cut bulk wire to correct length.3. Crimp terminal to each end of wire.4. For wire ends without crimped terminals, strip 1/2 in. (1.3 cm) from wire end. Heat terminal and fill with solder.Insert wire.FindPart orQtyNomenclatureSpecificationNo.Identifying No. Req.or DescriptionNo.1SN60WRP2ARSolderQQ-S-5712MS25036-1089Terminal, Lug Size 16-14AWG No. 10 Stud37243K211Terminal Lug FemaleMS25036QDISC, Fully InsulatedFigure D-4. Boost Pump Wiring Harness (Cont)D-7