TM 10-4610-229-24
Termination
Wire
Part or
Wire
No.
Identification No.
From
Find No.
To
Find No.
Length
1
M5086/1-14-Z
S3
2
S5
2
32.75 in.
2
M5086/1-14-Z
S2
2
SS1
2
84 in.
3
M5086/1-14-Z
S1
1
A
2
6.50 in.
4
M5086/1-14-Z
S1
1
ALT
3
96 in.
5
M5086/1-14-Z
A
2
SS1
4
84 in.
6
M5086/1-14-Z
A
2
ALT
5
96 in.
7
M5086/1-14-Z
F
2
FUEL TANK
2
21 in.
8
M5086/1-16-0
S3
2
0
2
5.75 in.
9
M5086/1-16-0
S3
2
T
2
9.25 in.
10
M5086/1-16-3
S3
2
S2
2
5.25 in.
11
M5086/1-16-3
S3
2
S1
2
7.75 in.
12
M5086/1-16-3
S1
2
F
2
4 in.
13
M5086/1-16-3
S1
2
S4
2
7 in.
14
M5086/1-16-3
S4
2
D1
2
4.75 in.
15
M5086/1-14-0
D1
2
L
2
5.5 in.
Figure D-4. Boost Pump Wiring Harness (Cont)
D-9