TM 10-4610-232-12
(1) Slide wires (53) through a new piece of shrink tubing (54). Make sure the new tubing is long enough to reach
the junction box and that the wires stick out at least ten inches from the end of the tubing.
(2) Push the shrink tubing on the wires until one end of it goes into body (55).
(3) Apply heat with the heat gun and shrink the tube onto the wires.
f. Slide bushing (52), retainer (51) and nut (50) over the wires and screw nut (50) onto body (55).
NOTE
Ensure that ball check (38C) is in the strainer.
f.1. Install ball check (38C), preformed packing (38B) and valve seat (38A) onto strainer (38).
g. Reassemble inlet strainer (38), primer fitting (39), tubes (42 and 43) with tube nuts (40) and compression rings
(41), elbow (45), nipple (46), bushing (47), bulkhead fitting (48) and gasket (49) and install in tank (61) as a unit.
h. Install nut (44) to secure the assembly in place. Tighten nut (44) securely to prevent leaks.
i. Install knob (33) on plate (36) and secure with screw (34) and washer (35).
j. Install hinges (32) on plate (36) and secure hinges to plate (36) and cover (37) using screws (29), washers (31) and
nuts (30).
k. Install nameplate (28) and secure with screws (25), washers (27) and nuts (26).
l. Install nameplate (24) and secure with screws (21), nuts (22) and washers (23).
m. Install gasket (20) on fitting (19) and secure fitting (19) on cover (37) with nut (18). Install bushing (17), valve (16),
and elbow (15).
n. Reassemble fitting (14), bushing (13), fitting (12), and gasket (11) and secure the subassembly to cover (37) with
nut (10).
o. Install bushing (8), elbow (7), gasket (9) in dust cover (6) and install adapter with dust cover on elbow (7).
p. Install assembled cover (37) on tank (61) and secure with capscrews (2), washers (3), washers (5) and nuts (4).
q. Reach inside tank and secure tubing (43) to fitting (14) using nut (1).
4-176 Change 2