WARNINGS
The booster pump is too heavy to be carried
equipment.
TM 10-4610-232-12
manually. Use proper lifting
Make sure electrical power is disconnected before working on unit. Failure to do
so could result in serious injury from electrical shock or moving parts.
REMOVAL.
a. Disconnect booster pump motor power cable (33, Figure 4-47, sheet 1).
b. Remove four Iockwashers (2), flat washers (3), and capscrews (1) holding bracket (7) to floor. Remove four
capscrews (4), Iockwashers (5), flat washers (6) and remove bracket (7).
c.
d.
e.
joint
Loosen tubing nut and remove tubing (8).
Remove clamp (9) and gasket (10).
NOTE
Some ROWPU's may not have spacer (14A).
Remove four capscrews (12), Iockwashers (13), flat washers (14), spacer (14A), piping assembly (11) and expansion
(15).
f. Loosen nuts(16) and remove drain line (17).
g. Remove fourcapscrews(18), Iockwashers (19), flat washers (20), nuts (21) and flat washers (22).
h. Remove four capscrews (24), Iockwashers (25), flat washers (26) and rubber washers (27). Remove pump
assembly (28) and gasket (23).
METHOD OF TAPING
Figure 4-47. Booster Pump Motor Assembly (sheet 2 of 2)
Change 2 4-181