TM 10-4610-232-12
I.
Remove four screws (22), four O-rings (23), cover (24), and gasket (25) from control top (13).
m. Remove lock nut (26), gasket (27), cord grip (28) and receptacle assembly (29) from cover (24).
n.
Remove packing gland (30), O-ring (31), O-ring (32), and O-ring (33) from housing (13).
o.
Remove plug (34) and blow-out plug (35) from housing (13).
p.
Remove vented plug (36) and air fitting (37) from housing (13).
REPAIR - CONTROL TOP.
Repair of control top is limited to replacement of damaged or defective components.
ASSEMBLY - CONTROL TOP.
CAUTION
Over tightening screws into the plastic control top housing will strip the threads in the housing. Do not
over tighten any screws installed into the control top housing.
a.
Install air fitting (37) and vented plug (36) into housing (13).
b.
Install blow-out plug (35) and plug (34) into housing (13).
c.
Install O-ring (33), O-ring (32), O-ring (31), and packing gland (30) into housing (13).
d.
Install receptacle assembly (29), cord grip (28), gasket (27), and lock nut (26) onto cover (24).
e.
Install gasket (25), cover (24), four O-rings (23), and four screws (22) onto housing (13).
f.
Strip .25 inch of insulation from end of wire (21) and slide wire through connector (15) and crimp terminal (20) onto
wire. Repeat as required for other wires as shown on wire tags.
g.
Install slide (19), spacer (18), and two screws (17) onto micro switch (4). Repeat for other micro switch.
h.
Install electrical connectors (15) onto micro switch (4). Repeat for other micro switch.
i.
Refer to wire tags and connect yellow and black wires to solenoid (7) using two butt splices (14).
j.
Place control top (13) onto actuator and install nut (12) onto actuator. Position nut as measured and marked
during disassembly.
k.
Refer to match markings made during disassembly, position control top (13) on actuator and install lock washer
(11), screw (10), and three socket head screws (9).
I.
Install gasket assembly (8), solenoid (7) and two screws (6).
m. Slide two micro switches (4) and (5) onto control top (13). Position each micro switch in accordance with
measurements and marks made during micro switch removal.
n.
Install gasket (3), cover (2), and four screws (1).
o.
Install water ejector (2A).
4-202.4 Change 7