TM 10-4610-239-10
TM 08580B-10/1
Table 2-3. Operator/Crew Preventive Maintenance Checks and Services
(Unit) (Continued)
B - Before
D - During
A - After
H - Hourly Interval
Interval
Procedures:
Equipment Is
Item
Item to be
Check for and have repaired
Not Ready/
No.
B D
A
W
Inspected
or adjusted as necessary
Available If:
23
R.O. Pump Motor
Wipe motor with a clean
cloth dampened with an ap-
proved cleaning solvent
(P-D-680).
Check oil level and lubri-
cate in accordance with lu-
bricating order, LO 10-
4610-239-12/LI 08580B-12
Inspect for signs of over-
heating or too much wear.
NOTE
A new pump may run hotter for a
few days. Change oil before first
startup; watch oil level during
break-in period.
Listen for uneven, knocking
Motor makes un-
sound
familiar sounds
during operation.
24
R.O. Pump drain
Inspect drain tube end to
Drain clogged and
tube end
ensure that drain is open
cannot be cleared.
Open restricted drain.
25
R.O. Pump cavity
Remove the wing nut and cover
seals and plungers
plate which are located at the top
center of pump
Plungers equipped
with rubber splash guards are now
exposed. Using spanner wrench,
tighten packing nut.
Inspect R.O. pump cavity to
Water level in
make sure excessive leakage
R.O. pump cavity
is not occurring:
rises near plungers
during operation.
CAUTION
Excessive leakage will contami-
nate the oil and score the plungers.
2-27