TM 10-4610-239-24
TM 08580B-24/3
REMOVAL.
a. Remove four screws (1), washers (2), cover (3), and gasket (4).
NOTE
Tag wires before removal.
b. Remove three screws (5) and terminal lugs (6).
c.
Remove sealing grip (7) from high-pressure switch (8).
d. Disconnect pressure tube nut (9) from adapter (10).
e. Remove two nuts (11), lockwashers (12), flat washers (13), screws (14), and high-pressure switch (8). Discard
lockwashers.
f.
Remove two adapters (10) and (15).
INSPECTION.
a. Inspect switch for broken case and damaged threads or components. Send damaged switch to Direct Support
Maintenance.
b. Inspect electric power cable for cracked or burned insulation, bare wires, damaged sealing grip and wire lugs.
Replace as required.
c.
Inspect mounting hardware for stripped threads and heads. Replace as required.
d. Inspect cover gasket for breaks and serviceability. Replace as required.
INSTALLATION.
a. Position high-pressure switch (8) and install two screws (14), flat washers (13), lockwashers (12), and nuts (11).
NOTE
Apply antiseize tape to all male pipe threads before installation.
b. Install adapter (10) and high-pressure tube (9).
c.
Install adapter (15).
d. Position sealing grip nut (7) on power cable and thread wires through adapter (15) into high-pressure switch
housing (8) and tighten sealing grip nut (7) on adapter (15).
2-188