TM 10-4610-239-24
TM 08580B-24/3
SECTION II. MAINTENANCE ALLOCATION CHART cont'd
FOR
WATER PURIFICATION UNIT, REVERSE OSMOSIS
(1)
(2)
(3)
(4)
(5)
(6)
Maintenance Level
Group
Maintenance
Tools and
Remarks
Field
Sustainment
Number
Component/Assembly
Function
Test
Code
Equipment
Unit
DS
GS
Depot
Ref Code
C
O
F
H
D
Cable Assembly W 44
Inspect
0.1
10
(Raw Water Pump
Test
0.2
10
NO.2)
Replace
0.5
6,10
Repair
1.0
6,10
Frame
Inspect
0.5
Replace
2.0
10
Repair
1.0
2.0
6,10
C
05
PUMP AND FRAME
Inspect
0.5
0.4
0.4
0.5
10
ASSEMBLY, BACKWASH
Test
0.7
0.5
6
Replace
4.0
7,10
Repair
1.0
2.0
2.0
8,9,10
Strainer Assy
Inspect
0.5
Replace
0.1
0.1
10
Repair
0.5
1,10
Pump Assembly,
Inspect
0.2
Backwash
Test
0.5
Replace
2.0
10
Repair
2.0
6,10
Pump, Backwash
Inspect
0.2
0.2
0.2
Replace
2.0
10
Repair
2.0
6,10
Motor, Electric,
Inspect
0.2
0.2
0.2
Backwash Pump
Test
0.5
6
Replace
2.0
6,10
Repair
2.0
6,10
Cable Assembly W 42
Inspect
0.1
(Backwash Pump)
Test
0.2
Replace
0.5
6,10
Repair
1.0
6,10
Frame
Inspect
0.5
10
Replace
2.0
10
Repair
1.0
1.0
6,10
C
06
Remove/Install
1.5
6
E
KW
Change 1 B-15