TM 10-4610-240-10
TM 08580C-10/1
T.O. 40W4-13-21
(9) Remove plug from INLET port on FOR USE WITH RADIOACTIVE CONTAMINATED WATER cartridge
and insert adapter into cartridge.
(10) Slide clamp over end of tubing.
(11) Attach tubing to adapter on INLET port and close clamp.
(12) Slideclamp over end of second section of 3/4 in. x 8in. flexible tubing.
(13) Remove plug from OUTLET port on FOR USE WITH RADIOACTIVE CONTAMINATED WAT ER cartridge
and insert adapter.
(14) Attach tubing to adapter on OUTLET port and close clamp.
f. Complete connection of NBC cartridge to second raw water tank (figure 2-78).
(1) Slideclamp over remaining end of 3/4 in. x 80 in. flexible tubing.
(2) Insert adapter into tubing and close clamp.
(3) Attach shoulder bushing, pipe coupling, and straight adapter to 1 1/2 in. discharge hose and connect to
NOTE
Do not operate chlorination feed pump during NBC operation.
g. During NBC operation, it is necessary to chlorinate the second tank by hand.
h. With the exception of the chlorination feed pump, operate the ROWPU using normal operating procedures.
2-99/(2-100 blank)