2-25. CABLE ASSEMBLY W45 (DISTRIBUTION PUMP) MAINTENANCE.
This task consists of:
a. Removal
b. Test
c. Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
Material/Parts Required
Tape, electrical (Appendix C, Section II, Item 31 )
Lockwasher (4) - MS35333-100
Equipment Condition
Reference
ROWPU shutdown (TM 10-461240-10).
Power shut down (power source manual).
Distribution pump cable assembly disconnected from ROWPU (TM 10-4610-240-10).
REMOVAL
a.
Unwrap cable assembly (1) from distribution pump assembly frame (2)
b.
Remove four screws (3), cover (4), and gasket (5).
NOTE
Tag wires by set before removal.
c.
Pull bundle of four wire sets (6) from conduit box (7).
d.
Set aside wire bundle with three cream-colored wires.
e.
Tag three other bundles with color of wires from power source.
f.
Remove twine (14) and electrical tape (8) from three tagged wire sets.
g.
Remove screw (17) securing grounding wire (16).
h.
Remove nut (13), lockwasher (12), three wire lugs (11), and flat washer (10) from screw (9) on each set of
wires (6) that have been untaped.
i.
Install flat washer (10), lugs of two cream-colored wires (11), lockwasher (12), and nut (13) on screw (9).
CAUTION
Wire insulation can be damaged when wires are pulled through conduit box Be
careful when pulling wires.
j.
Loosen sealing grip (15) and remove cable assembly (19) from conduit box (7).
2-120