TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-24. DISTRIBUTION PUMP ASSEMBLY MAINTENANCE.
This task consists of
a. Removal
b. Repair
c. Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
Material/Parts Required
Rags, wiping (Appendix C, Section II, Item 23)
Gasket (2) - 095X01 50CBUNA
Screw, drive (2) - MS21318-20
Equipment Condition
Reference
ROWPU shutdown (TM 104610-240-10).
Power shutdown (power source manual).
Inlet/outlet hoses removed (TM 10-4610-240-10).
Distribution pump cable assembly disconnected from ROWPU (TM 10-4610-240-10).
REMOVAL
Removal of the distribution pump is limited to removal of defective assembly from service
REPAIR
a. Disassembly.
(1)
Unwind cable assembly (1) from frame (20).
(2)
Remove screw (2), star washer (3), and cap (4) from electrical plug (5).
(3)
Remove locknut (14), flat washer (15), chains (9 and 13) and screw (16).
(4)
Remove plug (12) and gasket(11) from adapter (10).
(5)
Remove cap (8) from adapter (6).
(6)
Remove gasket (7) from adapter (6).
(7)
Remove two screws (19) and information plate (18) from frame (20).
b. Cleaning.
(1)
Wash all components with clean water and detergent.
(2)
Rinse components In clean water and dry with wiping rag.
2-116