TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-66. LOW PRESSURE SWITCH MAINTENANCE - continued.
e. Route wires (23) into low-pressure switch (18) and connect cable (22) to elbow connector (1) with sealing grip (2).
NOTE
White wires connects to COM lug. Black wires connects to NC lug.
f. Install two wire lugs (19), washers (20) and screws (21) on low pressure switch (18) as marked during removal..
g. Position wire lug (16) of green wire and install screw (17).
h. Install gasket (3), cover (4), chain lug (7), lockwasher (8) and screw (9) on low pressure switch (18).
i. Install three lockwashers (5) and screws (6) on low pressure switch (18).
j. Operate ROWPU (TM 10-4610-24010). Check for leaks and proper operation.
VIEW FROM BEHIND
CONTROL PANEL
2-235