2-68. CHEMICAL FEED PUMP MAINTENANCE.
This task consists of:
a. Service
b. Removal
c.
Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
Material/Parts Required
Tape, electrical (Appendix C, Sect II, Item 31)
Oil, lubricating (LO 5-4610-215-12/3)
Lockwasher (4) - MS35338-140
Lockwasher (2) - MS35338-108
Lockwasher (4) - MS35338-141
Equipment Condition
Reference
ROWPU shutdown (TM 10-4610-240-10).
Power shutdown (power source manual).
Chemical cans and frame removed (TM 10-4610-240-10).
SERVICE
a. Place suitable container (6 ounce capacity) below chemical feed pump drain plug (3).
b. Remove drain plug (3) and allow oil to drain into container.
c. Install drain plug (3) and remove fill plug (1).
d. Add oil through fill hole until oil level rises to center of sight glass (2).
e. Install fill plug (1).