TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
2-73.
FLUID PRESSURE DAMPENER MAINTENANCE - continued.
WARNING
Fluid pressure dampener is heavy/difficult to handle. Two personnel are required to move the fluid
pressure dampener.
e.
Remove two straps (15) and separate fluid pressure dampener (14) from frame supports (8).
INSTALLATION
WARNING
Fluid pressure dampener is heavy and difficult to handle. Two personnel are required to move the fluid
pressure dampener.
a.
Position fluid pressure dampener (14) on frame supports (8).
b.
Apply anti-seize tape to male fittings. Be sure to wrap tape in same direction as pipe thread.
c.
Install two straps (15), four flat washers (16), screws (17), lockwashers (6), and nuts (7).
d.
Install adapter (13) and elbow (5) on fluid pressure dampener (14).
e.
Install gasket (11), clamp halves (10), two screws (12), and two nuts (9).
f.
Install gasket (4), clamp halves (2), two screws (1), and two nuts (3).
g.
Operate ROWPU (TM 10-4610-240-10). Check for leaks and proper operation.
2-263